ISENTROPIC EFFICIENCY OF GAS TURBINE AXIAL COMPRESSORS AND THE OUTDOOR TEMPERATURE EFFECT
Abstract
This paper presents the calculation of the isentropic efficiency of a gas turbine axial compressor manufactured by Alstom. Isentropic efficiency shows how much energy is transformed in exergy and how much into anergy. This paper presents the calculation of axial compressor characteristics of an Alstom GT11N2 thermal power plant in Brestanica, Slovenia. The efficiency changes dependant on external temperatures during 2009 are also presented.
Downloads
References
T. Giampaolo: Gas Turbine Handbook – Principles and Practice, 4th edition; 2008
S. L. Dixon, C. A. Hall: Fluid mechanics and thermodynamics of turbo machinery, 6 Edition Book; 2010
J. H. Horlock: Advanced Gas Turbine Cycl, 1st Edition, 2003
M. Tuma, M. Sekavčnik: Energetski stroji in naprave – osnove in uporaba; 2005
J. Gašparinčić: Razvoj suvremenih energetskih postrojenja (Fakultet strojarstva i brodogradnje – Zagreb); 2012
Obratovalni podatki TE Brestanica za leto 2010
Projektna naloga Garancijske meritve PB4,5 – performance test report Alstom; 2001
I. Kuštrin, M. Sekavčnik: TE Brestanica PB5 – enostaven odprt plinski proces; 2009